Inspect, test, and maintain automatic sprinkler systems.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Provide properly protected cooking facilities.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Have approved installation, maintenance and testing program for fire alarm systems.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Properly select, install, inspect, or maintain portable fire extinguishes.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Have a battery powered remote alarm panel in a location accessible by operating personnel.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Have generator or other power source capable of supplying service within 10 seconds.
Severity F of L: no actual harm, potential for more than minimal harm, widespreadCorrected Feb 28, 2022
Ensure proper usage of power strips and extension cords.
Severity E of L: no actual harm, potential for more than minimal harm, patternCorrected Feb 28, 2022
Provide and implement an infection prevention and control program.
Severity D of L: no actual harm, potential for more than minimal harm, isolatedCorrected Jan 19, 2022
Ensure gas and vacuum systems are inspected and tested as part of a maintenance program.
Severity D of L: no actual harm, potential for more than minimal harm, isolatedCorrected Feb 28, 2022
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
Severity D of L: no actual harm, potential for more than minimal harm, isolatedCorrected Feb 28, 2022
Install corridor and hallway doors that block smoke.
Severity D of L: no actual harm, potential for more than minimal harm, isolatedCorrected Feb 28, 2022
Meet requirements for the installation and maintenance of medical gas and medical vacuum systems.
Severity D of L: no actual harm, potential for more than minimal harm, isolatedCorrected Feb 28, 2022